Skip to main content


AVA 300

Spectrometer: 300UltraShield™, standard bore, 54 mm
1H frequency: 300.13 MHz
Console: Avance 300
Probe head: 5 mm, DUAL 1H-13C with Z-gradient, without ATM
Sample changer: B-ACS 60
Temperature control: --
Temperature: Room temperature
TopSpin Version 2.1
Room: 23.0.16
Contact: NMR Department
 


AVA400

Spectrometer: Standard magnet, standard bore, 54 mm
¹H frequency: 400.13 MHz
Console: Avance III HD
Sample head: 5 mm, BBO BBF-H-D with Z-gradient
Sample changer: SampleCase^TM with 24 positions
Temperature control: BCU 05
Temperature: -80 °C to 100 °C
TopSpin Version 3.7.0
Room: 22.1.37
Contact: NMR Department


AVA 400 STUD

Spectrometer:UltraShield™ Plus 400, standard bore, 54 mm
1H frequency: 400.13 MHz
Console: Avance III
Sample cell: 5 mm, BBO BBF-H-D with Z-gradient
Sample changer: B-ACS 120
Temperature control: --
Temperature: Room temperature
TopSpin Version 3.6.5
Room: 33.0.80
Contact: NMR Department

 


AVA 400 NEW

Spectrometer: Ascend 400, standard bore, 54 mm
1H frequency: 400.30 MHz
Console: Avance III HD
Sample cell: 5 mm, BBO, BBF-H-D with Z-gradient
Sample changer: SampleXpress with 60 positions
Temperature control: BCU II
Temperature: 25 °C
TopSpin version: 3.5 pl 7
Room: 23.0.81
Contact: NMR Department


AVA 500 Physics

Spectrometer: Standard magnet, standard bore, 54 mm
1H frequency: 500.13 MHz
Console: Avance Neo
Sample head: 5 mm, CPP TCI 500S3 H&F-C/N-D
Sample changer: --
Temperature control: BCU II
Temperature: -40 °C – 80 °C
TopSpin Version 4.0.3
Room: 7.0.03 / 7.0.02a
Contact: Sprangers group
 

 


AVA 500 Chemistry

Spectrometer: Ascend 500, standard bore, 54 mm
1H frequency: 500.18 MHz
Console: Avance Neo
Sample head: 5 mm, CPP1.1 BBO 500S1 BB-H&F-D, with Z-gradient
Sample changer: SampleCase Plus with 60 positions
Temperature: 25 °C
TopSpin version 4.4.0
Room: 23.0.17
Contact: NMR Department


AVA 600 Physics I

Spectrometer: SpectroSpin 600, standard bore, 54 mm
¹H frequency: 599.93 MHz
Console: Avance Neo
Sample head: 5 mm, CPP TCI 600S3 H&F-C/N-D
Sample changer: --
Temperature control: BCU II
Temperature: -40 °C – 80 °C
TopSpin Version 4.0.08
Room: 7.0.03 / 7.0.02a
Contact: Sprangers Group
 


AVA 600 Chemistry

Spectrometer:600UltraShield™, standard bore, 54 mm
¹H frequency: 600.03 MHz
Console: Avance III HD
Sample head: TBIF, TBIP, TBON
Sample changer: --
Temperature control: BCU II, additional temperature control of the TBI heads with BVTE 3900
Temperature: -105 °C – 150 °C
TopSpin Version 3.6.2
Room: 22.1.37
Contact: Gschwind group
 


AVA 600 Physics II

Spectrometer:600UltraShield™, standard bore, 54 mm
1H frequency: 600.03 MHz
Console: Avance Neo
Sample head: 5 mm, PA BBO 600S3 BB-H&F-D Diff, CPP BBO 600S3 BB-H&F-D with Z-gradient
Sample changer: --
Temperature control:
Temperature: -40 °C – 80 °C for BBO, -105 °C – 185 °C for Diff
TopSpin version: 4.5.0
Room: 7.0.03 / 7.0.02a
Contact: Gschwind group
 


AVA 600 Cryo

Spectrometer:600UltraShield™, standard bore, 54 mm
¹H frequency: 600.28 MHz
Console: Avance III HD
Sample head: CPI2.1 TCI 600S3 H-C/N-D with Z-gradient
Sample changer: SampleJet
Temperature control: BCU 05
Temperature: -42 °C to 171 °C
TopSpin Version 3.7.0
Room: 22.1.04
Contact: Gschwind Group/NMR Department
 


AVA 800

Spectrometer: UltraStabilised, standard bore, 54 mm
1H frequency: 800.20
Console: Avance Neo
Sample head: CP CO 800S7 H-C/N-D with Z-gradient 
Sample changer: --
Temperature control: BCU 05
Temperature: -40 °C – 80 °C
TopSpin Version 4.0.3
Room: 7.0.03 / 7.0.02a
Contact: Sprangers group
 

To top